Looking for SOC for IT, endpoint or mobile? → fasterup.ai
FASTERUP OT · OT/SCADA DIVISION

We see the process network. We touch nothing.

Monitoring for industrial and SCADA networks through port mirroring or a TAP: the inventory of equipment that communicates, write commands and program downloads to PLCs, every new device and every remote access. No action on the process.

Schedule a 60–90 day pilotHow it works
411ICS/SCADA detection rules active on the sensor
3,149,120indicators in CYBER3 DATABASE (live)
47,942indicators observed by our own sensors (live)
2026-11-05last database update

Three things you learn in the first week

Inventory of equipment that communicates

IP and MAC addresses, vendor, services and ICS protocols for every device seen in traffic — without a single packet sent by us.

Commands to PLCs

Modbus writes, DNP3 select/operate, STOP, S7 program downloads and uploads, IEC-104 and CIP commands: who, when, from which workstation.

New devices and remote access

Any new address in the process network and any link to the outside or from the outside into ICS, flagged immediately.

TWO INSTALLATION MODES

Standard: mirroring or TAP. Optional: inline, listen only.

In standard mode the sensor receives a copy of the traffic from a mirrored switch port (SPAN) or a TAP: it is not on the data path. Inline (an IP-less bridge between router and switch) is available for evaluations, with the client's written consent, because a power loss or a sensor failure interrupts the link.

Mirroring / TAP (standard)

Traffic is copied to the sensor. The process notices nothing, whatever happens to the sensor.

Inline, listen only (optional)

Software bridge without an IP address; forwarded traffic never touches the packet filters. Measured at our office: 0 frames emitted by the sensor in 120 s, 0 packets dropped, ports at 1000/full.

Out-of-band management

The sensor is managed only through its own 4G modem and a dedicated encrypted tunnel; it asks nothing from the client's network.

Details →

WHAT WE SEE

Three families of findings, with real alert examples

Inventory and firmware

Versions and services read from traffic (SSH, HTTP, TLS, SMB, SNMP, ENIP identity, LLDP) → correlated offline with known CVEs, no active scanning.

Write commands and program downloads

Modbus (write, diagnostics, identity), DNP3 (select, operate, direct operate, restart, stop), S7 (STOP, write, program download/upload, PI), IEC-104 (commands, reset), CIP (write, reset).

New device / remote access

Any new address in the process network, remote access from outside, ICS → Internet links, Telnet and clear-text protocols.

Details →

PILOT

A 60–90 day pilot with no operational impact

Schedule the pilot